Rayleigh Instruments - Current Transformers
Our current transformers range of single phase and three phase current transformers includes moulded case, measuring, protection, toroidal, saturation, summation, core balanced, split core and high accuracy transformers, and of course Rayleigh Instruments patented easywire® current transformers.
-
RI-CT080 Single Phase Current Transformer
- Ranges: 150A to 1250A
- 5A or 1A Secondary output
- Cable/Busbar aperture : 50 x 10mm, 40 x 30mm or Ø40mm
- Sealable terminal cover
-
RI-CT090 Single Phase Current Transformer
- Ranges: 400A to 1600A
- 5A or 1A Secondary output
- Cable/Busbar aperture : 60 x 15mm, 50 x 30mm or Ø45mm
- Sealable terminal cover
-
RI-CT100 Single Phase Current Transformer
- Ranges: 400A to 2000A
- 5A or 1A Secondary output
- 90mm width
- Busbar aperture : 60 x 30mm
- Sealable terminal cover
-
RI-CT110 Single Phase Current Transformer
- Ranges: 200A to 2000A
- 5A or 1A Secondary output
- Cable/Busbar aperture : 60 x 30mm, 80 x 10mm, 50 x 50mm or Ø60mm
- Sealable terminal cover
-
easywire Three Phase Current Transformer - RI-CT250-EW
- Ranges: 630 to 1600A (330mV Secondary)
- Cable/Busbar aperture : 3 @ 50 x 54mm
- 70mm hole centres
- Accuracy Class 1
-
Rayleigh Instruments RI-CT250 Three Phase Current Transformer
- Ranges: 630A to 1600A
- 5A Secondary output
- Cable/Busbar aperture: 3 @ 54 x 50mm
- 70mm hole centres
- Primary flow arrows on case
- Sealable terminal cover
- Supplied with DIN-Rail mounting clip, Busbar fixings and mounting feet
-
IME TA540 Solid Core Single Phase Measuring Current Transformer
- Measuring current transformer
- Range 300 to 1200A (5A or 1A Secondary)
- Busbar window 50.5x12.5mm & 40.5x20.5mm
- Cable aperture 40mm
-
IME TASH TAS63 Single Phase Solid Core Measuring Current Transformer
- Measuring and protection current transformer (formerly TAS63)
- Ranges: 150 to 1600A (1A or 5A Secondary)
- Busbar window 64 x 19mm, 51 x 20mm, 41 x 21mm or 10 x 24mm
-
IME TASI TAS64 Single Core Single Phase Measuring Current Transformer
- Measuring current transformer (formerly TAS64)
- Ranges: 200 to 1600A (1A or 5A Secondary)
- Busbar window 64 x 11mm, 51 x 31mm
-
IME TASM (formerly TAS80) Single Phase Current Transformer
- Measuring and protection current transformer (formerly TAS80)
- Ranges: 300 to 2500A (1A or 5A Secondary)
- Busbar window 82 x 32mm
-
IME TASN (formerly TAS81) Single Phase Current Transformer
- Measuring current transformer
- Ranges: 400 to 2500A (1A or 5A Secondary)
- Busbar window 81 x 11mm, 64 x 31mm, 31 x 51mm
- Supplied with busbar mounting bracket
- Secondary terminals M4 screws and 6.3 x 0.8mm fast-on
-
IME TAQC...S (formerly TAQ10...S) High Accuracy Single Phase Current Transforme...
- High accuracy current transformer (formerly TAQ10...S)
- Ranges: 5 to 1500A (1A or 5A Secondary)
- Wound primary
-
Rayleigh Instruments RI-CTS812 Split Core Measuring CT
- From 500A to 1600A Primary currents
- 5A or 1A Secondary output
- 145mm width
- 80 x 120.5mm aperture
-
Rayleigh Instruments RI-CTS816 Split Core Measuring CT
- From 2000A to 5000A Primary currents
- 5A or 1A Secondary output
- 186mm width
- 81 x 160.5mm aperture
-
IME TAWA (formerly TAS63P) Single Phase Protection Current Transformer
- Protection current transformer (formerly TAS63P)
- Ranges: 150 to 1600A (1A or 5A Secondary)
- Busbar window 64 x 19mm, 51 x 20mm, 41 x 21mm or 10 x 24mm