Rayleigh Instruments - Current Transformers
Our current transformers range of single phase and three phase current transformers includes moulded case, measuring, protection, toroidal, saturation, summation, core balanced, split core and high accuracy transformers, and of course Rayleigh Instruments patented easywire® current transformers.
-
IME TAQB TAQ6 Single Phase Winding Primary Current Transformer
- Measuring current transformer (formerly TAQ6)
- Ranges: 5 to 100A (1A or 5A Secondary)
- Wound primary
-
IME TAQC TAQ10 Wound Primary Single Phase Current Transformer
- Measuring current transformer (formerly TAQ10)
- Ranges: 5 to 300A (1A or 5A Secondary)
- Bar primary
-
IME TAQD (formerly TAQ20) Single Phase Current Transformer
- Measuring current transformer (formerly TAQ20)
- Ranges: 5 to 600A (1A or 5A Secondary)
- Bar primary
-
IME TAQC...S (formerly TAQ10...S) High Accuracy Single Phase Current Transforme...
- High accuracy current transformer (formerly TAQ10...S)
- Ranges: 5 to 1500A (1A or 5A Secondary)
- Wound primary
-
IME TA327...S High Accuracy Single Phase Current Transformer
- High accuracy CT
- Ranges: 50 to 600A
- 5A or 1A Secondary output
- Busbar/Cable aperture 32.5 x 10.5mm, 25.5 x 15.5mm or Ø27mm
- Accuracy: cl. 0.2s - 0.2 - 0.5s
-
IME TA432...S High Accuracy Single Phase Current Transformer
- High accuracy current transformer
- Range 100 to 1000A
- Busbar window 40.5x10.5mm, 32.5x20.5mm & 25.5x25.5mm
- Cable aperture 32mm
-
Rayleigh Instruments RI-CTS023 Split Core Measuring CT
- From 100A to 400A Primary currents
- 5A or 1A Secondary output
- 89mm width
- 21 x 32mm aperture
-
Rayleigh Instruments RI-CTS058 Split Core Measuring CT
- From 250A to 1000A Primary currents
- 5A or 1A Secondary output
- 115mm width
- 50.1 x 80mm aperture
-
Rayleigh Instruments RI-CTS088 Split Core Measuring CT
- From 250A to 1000A Primary currents
- 5A or 1A Secondary output
- 145mm width
- 80.5 x 80.5mm aperture
-
Rayleigh Instruments RI-CTS812 Split Core Measuring CT
- From 500A to 1600A Primary currents
- 5A or 1A Secondary output
- 145mm width
- 80 x 120.5mm aperture
-
Rayleigh Instruments RI-CTS816 Split Core Measuring CT
- From 2000A to 5000A Primary currents
- 5A or 1A Secondary output
- 186mm width
- 81 x 160.5mm aperture
-
IME TAWA (formerly TAS63P) Single Phase Protection Current Transformer
- Protection current transformer (formerly TAS63P)
- Ranges: 150 to 1600A (1A or 5A Secondary)
- Busbar window 64 x 19mm, 51 x 20mm, 41 x 21mm or 10 x 24mm
-
IME TAWB TAS80P Single Phase Protection Class 5P5 5P10 5P15 5P20 Current Transfo...
- Protection current transformer (formerly TAS80P)
- Ranges: 300 to 2500A (1A or 5A Secondary)
- Busbar window 82 x 32mm
-
IME TAWC TAS125P Single Phase Protection Class 5P5 5P10 5P15 5P20 Current Trans...
- Protection current transformer (formerly TAS125P)
- Ranges: 400 to 4000A (1A or 5A Secondary)
- Busbar window 127 x 54mm
- Secondary terminals M4 screws and 6.3 x 0.8mm fast-on
- Supplied with fixing feet
- Optional sealable terminal cover (ATACOP03)
- Weight 3600g
-
IME TAVA (formerly TAQ20P) Single Phase Current Transformer
- Protection current transformer (formerly TAQ20P)
- Ranges: 5 to 600A (1A or 5A Secondary)
- Bar primary