Rayleigh Instruments - Current Transformers
Our current transformers range of single phase and three phase current transformers includes moulded case, measuring, protection, toroidal, saturation, summation, core balanced, split core and high accuracy transformers, and of course Rayleigh Instruments patented easywire® current transformers.
-
Thiim LMWB Load Monitoring Relay - Real Power Watt - 45 mm. 2 C/O
- True power monitor for motors and other loads
- Temperature monitoring of motor windings
- Single and symmetric 3Ø loads
- Min. and max. monitoring
- Adjustable start-up delay 1…100s
- Off delay 0.1…50s
- Recognition of disconnected load
- Reset Key
- Fault latch
- Selectable supply voltages
-
Rayleigh Instruments RI-D36-80-P 80A Single Phase Kilowatt Hour Meter With Pulse...
- Single phase energy meter
- Accuracy Class 1
- 80A Direct connected
- 36mm wide DIN rail mounting
- LCD display
- Measured Voltage 230V 50/60Hz
- Pulse output
-
Rayleigh Instruments RI-D19-80-C 80A Single Phase Kilowatt Hour Meter Non MID Wi...
- Single phase energy meter
- Accuracy Class 1
- 80A Direct connected
- Counts up regardless of energy direction
- 19.5mm wide DIN rail mounting
- LCD display
- Measured Voltage 230V 50/60Hz
- Modbus RS485 output
-
Rayleigh Instruments RI-76-100-P 100A Single Phase Network MID Certified Kilowat...
- Single phase network active energy meter
- MID Certified (B and D)
- 100A Direct connected
- Counts up regardless of energy direction
- 76mm wide/4 module
- LCD Display 5+2= 99999.99
- Measured voltage 230/415V 50/60Hz
- Pulse output
-
IME TAI200 TAIA Solid Core Single Phase Measuring Current Transformer
- Measuring current transformer (formerly TAI200)
- Ranges: 50 to 250A (1A or 5A Secondary)
- Busbar window 20 x 5mm
- 22mm dia cable aperture
-
Easywire Patented MRJ4M-SL Split Load "Plug n Play" Din Rail Mounted M...
- Single and 3 phase 4 wire network , balanced or unbalanced load operation
- Double CT Connection
- Built in Dual Energy pulse output , configured to either kwh per load or kwh and kVArh (reative) per load and RS485 MODBUS communication
- 330mV current transformer input
-
Easywire Patented MRJ4M "Plug n Play" Din Rail Mounted Multi Function ...
- Single and 3 phase 4 wire network , balanced or unbalanced load operation
- Integrated Built in single pulsed output and RS485 Modbus/RTU
- 4 module DIN rail mounting
- 330mV current transformer input
-
Rayleigh Instruments RI-78-80-C 80A Single Phase Network MID Certified Kilowatt ...
- Single phase network active energy meter
- MID Certified (B and D)
- 80A Direct connected
- Counts up regardless of energy direction
- 78mm wide/4 Module
- Din Rail Mounted
- LCD Display 5+2= 99999.99
- Measured voltage 230V 50 Hz
- RS485 / Modbus RTU and Pulse output