Rayleigh Instruments - Current Transformers
Our current transformers range of single phase and three phase current transformers includes moulded case, measuring, protection, toroidal, saturation, summation, core balanced, split core and high accuracy transformers, and of course Rayleigh Instruments patented easywire® current transformers.
-
IME TA432...S High Accuracy Single Phase Current Transformer
- High accuracy current transformer
- Range 100 to 1000A
- Busbar window 40.5x10.5mm, 32.5x20.5mm & 25.5x25.5mm
- Cable aperture 32mm
-
IME TA327...S High Accuracy Single Phase Current Transformer
- High accuracy CT
- Ranges: 50 to 600A
- 5A or 1A Secondary output
- Busbar/Cable aperture 32.5 x 10.5mm, 25.5 x 15.5mm or Ø27mm
- Accuracy: cl. 0.2s - 0.2 - 0.5s
-
IME TA540 Solid Core Single Phase Measuring Current Transformer
- Measuring current transformer
- Range 300 to 1200A (5A or 1A Secondary)
- Busbar window 50.5x12.5mm & 40.5x20.5mm
- Cable aperture 40mm
-
IME TA432 Solid Core Single Phase Measuring Current Transformer
- Measuring current transformer
- Range 100 to 1000A
- Busbar window 40.5x10.5mm, 32.5x20.5mm & 25.5x25.5mm
- Cable aperture 32mm
-
IME TA426 Single Phase Measuring Current Transformer
- Measuring current transformer
- Ranges: 150 to 800A
- 5A or 1A Secondary output
- Busbar/Cable aperture 40.5 x 12.5mm, 32.5 x 10.5mm or Ø26mm
-
IME TA327 Solid Core Single Phase Measuring Current Transformer
- Passing cable/ bus bar primary
- Ranges: 50 to 600A
- 5A or 1A Secondary output
- Busbar/Cable aperture 32.5 x 10.5mm, 25.5 x 15.5mm or Ø27mm
- Accuracy: cl. 0.5 - 1 - 3
-
IME TA221 Single Phase Current Transformer
- Measuring current transformer
- Ranges: 40 to 300A
- 5A or 1A Secondary output
- Busbar/Cable aperture : 20.5 x 10.5mm or Ø21mm
-
IME TAIBB Solid Core Single Phase Measuring Current Transformer
- Ranges: 40 to 300A (5A Secondary), 40 to 200A (1A Secondary)
- Busbar window 16x12,5mm & ø 21mm Diameter able aperture
- Accuracy class :- cl.0,5 - 1 - 3
- Rated burden :- 1...7.5VA
-
easywire Three Phase Current Transformer - RI-CT249-EW
- Ranges: 60 to 160A (330mV Secondary)
- Cable/Busbar aperture : 3 @ 20 x 16mm
- 29mm hole centres
- Accuracy Class 1
-
Rayleigh Instruments RI-CT248 Three Phase Current Transformer
- Ranges: 250A to 630A
- 5A Secondary output
- Cable/Busbar aperture: 3 @ 31 x 31mm
- 45mm hole centres
- Primary flow arrows on case
- Sealable terminal cover
- Supplied with DIN-Rail mounting clip, Busbar fixings and mounting feet
-
easywire Three Phase Current Transformer - RI-CT248-EW
- Ranges: 250 to 630A (330mV Secondary)
- Cable/Busbar aperture : 3 @ 31 x 31mm
- 45mm hole centres
- Accuracy Class 1
-
Rayleigh Instruments RI-CT242 Three Phase Current Transformer
- Ranges 60A to 250A
- 5A Secondary output
- Cable/Busbar aperture: 3 @ 21 x 25mm
- 35mm hole centres
- Primary flow arrows on case
- Sealable terminal cover
- Supplied with DIN-Rail mounting clip, Busbar fixings and mounting feet
-
easywire Three Phase Current Transformer - RI-CT242-EW
- Ranges: 60 to 250A (330mV Secondary)
- Cable/Busbar aperture : 3 @ 25 x 21mm
- 35mm hole centres
- Accuracy Class 1
-
Rayleigh Instruments RI-CT240 Three Phase Current Transformer
- Ranges: 60A to 200A
- 5A Secondary output
- Cable/Busbar aperture: 3 @ 30 x 15.5mm
- 25mm hole centres
- Primary flow arrows on case
- Sealable terminal cover
- Supplied with DIN-Rail mounting clip, Busbar fixings and mounting feet
-
easywire Three Phase Current Transformer - RI-CT240-EW
- Ranges: 60 to 200A (330mV Secondary)
- Cable/Busbar aperture : 3 @ 15 x 30mm
- 25mm hole centres
- Accuracy Class 1