Rayleigh Instruments - Current Transformers
Our current transformers range of single phase and three phase current transformers includes moulded case, measuring, protection, toroidal, saturation, summation, core balanced, split core and high accuracy transformers, and of course Rayleigh Instruments patented easywire® current transformers.
-
RI-CT160 Single Phase Current Transformer
- Ranges: 400A to 6000A
- 5A or 1A Secondary output
- Busbar aperture: 54 x 127mm
- Sealable terminal cover
-
RI-CT160H Single Phase Current Transformer - Horizontal Mounting
- Ranges: 400A to 6000A
- 5A or 1A Secondary output
- Busbar aperture: 54 x 127mm
- Sealable terminal cover
-
easywire Three Phase Current Transformer - RI-CT248-EW
- Ranges: 250 to 630A (330mV Secondary)
- Cable/Busbar aperture : 3 @ 31 x 31mm
- 45mm hole centres
- Accuracy Class 1
-
Rayleigh Instruments RI-CT248 Three Phase Current Transformer
- Ranges: 250A to 630A
- 5A Secondary output
- Cable/Busbar aperture: 3 @ 31 x 31mm
- 45mm hole centres
- Primary flow arrows on case
- Sealable terminal cover
- Supplied with DIN-Rail mounting clip, Busbar fixings and mounting feet
-
easywire Three Phase Current Transformer - RI-CT250-EW
- Ranges: 630 to 1600A (330mV Secondary)
- Cable/Busbar aperture : 3 @ 50 x 54mm
- 70mm hole centres
- Accuracy Class 1
-
Rayleigh Instruments RI-CT250 Three Phase Current Transformer
- Ranges: 630A to 1600A
- 5A Secondary output
- Cable/Busbar aperture: 3 @ 54 x 50mm
- 70mm hole centres
- Primary flow arrows on case
- Sealable terminal cover
- Supplied with DIN-Rail mounting clip, Busbar fixings and mounting feet
-
Rayleigh Instruments RI-CTS036 Single Phase Clip On Mini Split Core Current Tran...
- 250A to 600A Primary
- 5A or 1A Secondary
- 57.5mm width
- 36mm cable aperture
- Integral 1 metre cable
- Snap together housing
- Compact design
- Primary current flow indication
-
Rayleigh Instruments TAS-XH-1250 Single Phase Split Core Current Transformer
- Split core current transformer
- Ranges: 70 – 600A (333mV Secondary)
- Cable aperture 32x32mm
- Supplied with 1 meter integral cable.
- Class 1 Accuracy
-
Rayleigh Instruments RI-CTS023 Split Core Measuring CT
- From 100A to 400A Primary currents
- 5A or 1A Secondary output
- 89mm width
- 21 x 32mm aperture
-
Rayleigh Instruments RI-CTS058 Split Core Measuring CT
- From 250A to 1000A Primary currents
- 5A or 1A Secondary output
- 115mm width
- 50.1 x 80mm aperture
-
Rayleigh Instruments RI-CTS088 Split Core Measuring CT
- From 250A to 1000A Primary currents
- 5A or 1A Secondary output
- 145mm width
- 80.5 x 80.5mm aperture
-
Rayleigh Instruments RI-CTS812 Split Core Measuring CT
- From 500A to 1600A Primary currents
- 5A or 1A Secondary output
- 145mm width
- 80 x 120.5mm aperture
-
Rayleigh Instruments DBP58/3 5A Class 1 Multi-Tap Split Core Measuring Current T...
- 63mm Dia Cable Aperture
- Multi-tap Split Core CT - 200, 400, 600, 800, 1000 / 5A
- Housing Material Self extinguishing Nylon IEC185 classification VO according to UL-94
- Weight 0.95Kg