Single Phase CTs
We stock an extensive range of solid core single phase moulded case current transformers.
These single phase transformers are suitable for monitoring current flow in commercial, industrial or utility applications. They are designed to connect any standard metering or relay product requiring a 5A or 1A output and are available with comprehensive Primary current input ranges.
-
RI-CT160 Single Phase Current Transformer
- Ranges: 400A to 6000A
- 5A or 1A Secondary output
- Busbar aperture: 54 x 127mm
- Sealable terminal cover
-
RI-CT160H Single Phase Current Transformer - Horizontal Mounting
- Ranges: 400A to 6000A
- 5A or 1A Secondary output
- Busbar aperture: 54 x 127mm
- Sealable terminal cover
-
IME TAIBB Solid Core Single Phase Measuring Current Transformer
- Ranges: 40 to 300A (5A Secondary), 40 to 200A (1A Secondary)
- Busbar window 16x12,5mm & ø 21mm Diameter able aperture
- Accuracy class :- cl.0,5 - 1 - 3
- Rated burden :- 1...7.5VA
-
IME TA221 Single Phase Current Transformer
- Measuring current transformer
- Ranges: 40 to 300A
- 5A or 1A Secondary output
- Busbar/Cable aperture : 20.5 x 10.5mm or Ø21mm
-
IME TA327 Solid Core Single Phase Measuring Current Transformer
- Passing cable/ bus bar primary
- Ranges: 50 to 600A
- 5A or 1A Secondary output
- Busbar/Cable aperture 32.5 x 10.5mm, 25.5 x 15.5mm or Ø27mm
- Accuracy: cl. 0.5 - 1 - 3
-
IME TA426 Single Phase Measuring Current Transformer
- Measuring current transformer
- Ranges: 150 to 800A
- 5A or 1A Secondary output
- Busbar/Cable aperture 40.5 x 12.5mm, 32.5 x 10.5mm or Ø26mm
-
IME TA432 Solid Core Single Phase Measuring Current Transformer
- Measuring current transformer
- Range 100 to 1000A
- Busbar window 40.5x10.5mm, 32.5x20.5mm & 25.5x25.5mm
- Cable aperture 32mm
-
IME TA540 Solid Core Single Phase Measuring Current Transformer
- Measuring current transformer
- Range 300 to 1200A (5A or 1A Secondary)
- Busbar window 50.5x12.5mm & 40.5x20.5mm
- Cable aperture 40mm
-
IME TASH TAS63 Single Phase Solid Core Measuring Current Transformer
- Measuring and protection current transformer (formerly TAS63)
- Ranges: 150 to 1600A (1A or 5A Secondary)
- Busbar window 64 x 19mm, 51 x 20mm, 41 x 21mm or 10 x 24mm
-
IME TASI TAS64 Single Core Single Phase Measuring Current Transformer
- Measuring current transformer (formerly TAS64)
- Ranges: 200 to 1600A (1A or 5A Secondary)
- Busbar window 64 x 11mm, 51 x 31mm
-
IME TASN (formerly TAS81) Single Phase Current Transformer
- Measuring current transformer
- Ranges: 400 to 2500A (1A or 5A Secondary)
- Busbar window 81 x 11mm, 64 x 31mm, 31 x 51mm
- Supplied with busbar mounting bracket
- Secondary terminals M4 screws and 6.3 x 0.8mm fast-on
-
IME TASL TAS65 Solid Core Single Phase Measuring Current Transformer
- Measuring and protection current transformer (formerly TAS65)
- Ranges: 200 to 2000A (1A or 5A Secondary)
- Busbar window 65 x 32mm
-
IME TASO TAS84 Single Phase Measuring Current Transformer - Terminals On Vertica...
- Ranges: 300 to 2500A (1A or 5A Secondary)
- Busbar window 84 x 34mm
- Accuracy class: cl.0,5 - 1
- Rated burden 2...30VA
-
IME TASM (formerly TAS80) Single Phase Current Transformer
- Measuring and protection current transformer (formerly TAS80)
- Ranges: 300 to 2500A (1A or 5A Secondary)
- Busbar window 82 x 32mm
-
IME TAMP TAS102 Solid Core Single Phase Measuring Current Transformer
- Measuring current transformer (formerly TAS102)
- Ranges: 800 to 3000A (1A or 5A Secondary)
- Busbar window 102 x 38mm