Datexel - I/O Modules
The DATEXEL range of signal conditioners includes Transmitters, Temperature converters (Both analogue and digital), galvanic isolators, signal splitters, distributed I/O modules, A/D interface modules for PLC, Trip amplifiers, Power suppliers, current loop isolators, digital meters and indicators.
Datexel Strategic UK Partner Products are available to our UK Customers.
-
Datexel DAT 3580-MBTCP Ethernet Gateway Modbus TCP Modbus RTU
- D2 Din rail mounting
- Bidirectional USB – RS485/422 converter
- 22.5mm DIN rail mounting enclosure
- Supply 10…30Vdc, 9…18Vac or 18…30Vac
-
Datexel DAT 3130 Distributed I/O Module 4 digital inputs + 4 relay outputs on RS...
- Field Bus data acquisition
- Master/Slave communication on RS-485 network
- MODBUS RTU/ASCII protocol
- 4 digital inputs
- 4 relay outputs (2 SPDT + 2 SPST)
- Watch-Dog alarm
- Four ways galvanic isolation 2000 Vac
- High accuracy
- EMC compliance – CE Mark
- In compliance to EN-50022 DIN rail mounting
-
Datexel DAT 4520 Din rail universal input PC configurable converter. Input: mV, ...
- Tc, RTD, Res, mV, V, mA, Potentiometer configurable input
- 0 to 10V, 0 to 20mA configurable output
- PC configurable
- 2000 Vac galvanic isolation between input, output
- EMC compliance – CE mark
- Suitable for DIN rail mounting
-
Datexel DAT 3140 Data Acquisition Distributed I/O Module 4 digital inputs + 8 NP...
- Field-Bus remote data acquisition
- Modbus Slave device on RS-485
- Modbus RTU/ Modbus ASCII protocol
- 4 digital inputs
- 8 digital outputs type NPN
- Watch-Dog alarm
- Galvanic isolation on all ways
- High accuracy
- UL / CE mark
- In compliance to EN-50022 DIN rail mounting
-
Datexel DAT 3011 Remote I/O Module Universal I/O on RS-485 Network
- Field-Bus remote data acquisition
- Modbus Slave device on RS-485
- Modbus RTU Protocol
- 1 Universal Analogue Input + 1 Analogue Input V/mA
- 2 Analogue Outputs 0-20mA
- 3 Digital Inputs
- 1 SSR Digital Output + 2 SPST Relay Outputs
- Watch-Dog Alarm
- Remotely Configurable
- 1500 Vac galvanic isolation on all the ways
- High Accuracy
- UL / CE mark
- DIN rail mounting in compliance with EN-50022
-
Datexel DAT 3014 Remote I/O module 4 channel RTD Input on RS-485 network
- Field-Bus remote data acquisition
- Modbus Slave device on RS-485
- Modbus RTU/ Modbus ASCII protocol
- 4 channels input
- Input configurable for RTD, Resistance and Potentiometer
- Watch-Dog Alarm
- Remotely Configurable
- 2000 Vac 3-ways Galvanic Isolation
- High Accuracy
- UL / CE mark
- DIN rail mounting in compliance with EN-50022