Home
>
-
Rayleigh Instruments - Electrical Transducers
Rayleigh Instruments - Electrical Transducers
-
- DIN rail mounting electronic galvanically isolated transducer
- Inputs 0…5mA, 0…20mA or 4…20mA
- Outputs 0…5mA, 0…20mA, 4…20mA or 10V
- 4 module DIN rail mounting
- Available with 230Vac, 115Vac and 20-150Vdc auxiliary supply
Call for Prices
-
- DC current/voltage transducer
- Ratio 1:1
- Accuracy 0.5
- Input current 4…20mA - unidirectional (or other value on request from 1…500mA)
- Input voltage 0…60mV - unidirectional (or other value on request from 50mV…400V)
- Choice of output 0…5mA, 0…10mA, 0…20mA, 4…20mA
- 4 module DIN rail mounting
- Available with 230Vac, 115Vac and 20-150Vdc and 150-250Vdc auxiliary supply
Call for Prices
-
- Direct connected DC current signal separator
- Ratio 1:1
- Self supplied
- Input 0-5mA, 0-10mA, 0-20mA, 4-20mA
- Output 0-5mA, 0-10mA, 0-20mA, 4-20mA
Call for Prices
-
- Direct connected DC current transducers
- Accuracy class 0.5 (class 0.2 frequency)
- Input voltage 0…10V up to 0…600Vdc - bidirectional from ± 5mA to ± 300V
- Choice of output 0…20mA, 4…20mA, 0…10Vdc
- 6 module DIN rail mounting
- Available with 230Vac, 115Vac and 20-30Vdc, 40-60Vdc, 90-140Vdc and 180-250Vdc auxiliary supply
Call for Prices
-
- Direct connected DC current transducers
- Accuracy class 0.5 (class 0.2 frequency)
- Input current 0…500µA up to 0…1.5Adc - bidirectional from ± 250µA to ± 750mA
- Choice of output 0…20mA, 4…20mA, 0…10Vdc
- 6 module DIN rail mounting
- Available with 230Vac, 115Vac and 20-30Vdc, 40-60Vdc, 90-140Vdc and 180-250Vdc auxiliary supply
Call for Prices
-
- Fully programmable transducer
- Single or 3-phase, balanced or unbalanced load or via voltage transformer
- Current input via current transformer -/1A or -/5A
- True R.M.S. measurements
- 80…500Vac phase/phase
- 50…300Vac single phase measured voltage
- Programmable measured quantity - active power - reactive power - apparent power - power factor - phase angle - power demand – frequency
- Analogue outputs 0…5mA, 0…10mA, 0…20mA, 4…20mA, 0…10V or 1…5Vdc
- Accuracy class 0.5 (class 0.2 frequency)
- LCD indicator for programming and display
- All parameters programmable from front cover 3 keys
- 8 module DIN rail mounting
- Available with 230Vac, 115Vac and 20-150Vdc auxiliary supply
Call for Prices
-
- Single phase AC
- True R.M.S measurement
- AC Voltage input
- Accuracy 0.5 (20…120%.In)
- Dip switch programmable current or voltage analogue output
- Available with 230Vac, 115Vac and 20…150Vdc auxiliary supply
Call for Prices
-
- Alternating voltage transducer
- Single phase AC
- AC Voltage input
- Accuracy 0.5 (20…120%.In)
- Dip switch programmable current or voltage analogue output
- Available with 230Vac, 115Vac and 20…150Vdc auxiliary supply
Call for Prices
-
- True R.M.S measurement
- Accuracy 0.5 (20…120% In)
- AC Voltage input
- DC Current or voltage output
- Self supplied auxiliary
Call for Prices
-
- Single phase AC
- True R.M.S measurement
- Accuracy 0.5 (20…120% In)
- Current input 1, 1.2, 5 or 6A
- Dip switch programmable current or voltage analogue output
- Available with 230Vac, 115Vac and 20…150Vdc auxiliary supply
Call for Prices
-
- Choice of supply voltages
- Single phase AC
- Accuracy 0.5 (20…120%.In)
- Current input 1, 1.2, 5 or 6A
- Dip switch programmable current or voltage analogue output
- Available with 230Vac, 115Vac and 20…150Vdc auxiliary supply
Call for Prices
-
- Alternating current transducer
- Self supplied auxiliary
- Two module
- Single phase AC
- Accuracy 0.5 (20…120% In)
- Current input 1, 1.2, 5 or 6A
Call for Prices
-
- Measures DC current with proportional DC analogue output, Hall Effect
- Cable aperture Ø35mm
- CT with built in transducer
- Measured current up to 1000A dc
- AC or DC supply voltage
Call for Prices
-
- 3 Ø, 3 or 4 wire or Aron
- -/1A or -/5A CT input (Primary 1…5000A)
- 4 Quadrant measurement
- Digital inputs
- Digital, Alarm relay and Analogue outputs
- Modbus connection
- Software for programming and data interrogation supplied
Call for Prices
-
- Input Current : 0…1A, 0…2A, 0…3A, 0…4A, 0…5A (AC)
- Output Mode : 0…20mA, 4…20mA, ±20mA, 20…0mA, 20…4mA, 0…5V, 0…10V, ±5V, ±10V, 10…0V
- Supply Voltage : 10…36V DC
- Response Time : <350ms
Call for Prices