NEED HELP ? - Call : +44 (0)1245 428500 or email : sales@rayleigh.com
OFFICE HOURS : 9:00am - 5:30pm GMT/BST Monday to Friday

Rayleigh Instruments - Electrical Transducers

Items 1 to 15 of 21 total

Page:
  1. 1
  2. 2

Grid  List 

  • IME TM3G - Active Signal Separators

    • DIN rail mounting electronic galvanically isolated transducer
    • Inputs 0…5mA, 0…20mA or 4…20mA
    • Outputs 0…5mA, 0…20mA, 4…20mA or 10V
    • 4 module DIN rail mounting
    • Available with 230Vac, 115Vac and 20-150Vdc auxiliary supply
    Call for Prices

  • IME Tema SG - TM2G Direct Current and Voltage Signal Separator Transducers

    • DC current/voltage transducer
    • Ratio 1:1
    • Accuracy 0.5
    • Input current 4…20mA - unidirectional (or other value on request from 1…500mA)
    • Input voltage 0…60mV - unidirectional (or other value on request from 50mV…400V)
    • Choice of output 0…5mA, 0…10mA, 0…20mA, 4…20mA
    • 4 module DIN rail mounting
    • Available with 230Vac, 115Vac and 20-150Vdc and 150-250Vdc auxiliary supply
    Call for Prices

  • IME TM1G - DC Direct Current Signal Separator

    • Direct connected DC current signal separator
    • Ratio 1:1
    • Self supplied
    • Input 0-5mA, 0-10mA, 0-20mA, 4-20mA
    • Output 0-5mA, 0-10mA, 0-20mA, 4-20mA
    Call for Prices

  • IME TM1V - DC Voltage Isolated Transducer

    • Direct connected DC current transducers
    • Accuracy class 0.5 (class 0.2 frequency)
    • Input voltage 0…10V up to 0…600Vdc - bidirectional from ± 5mA to ± 300V
    • Choice of output 0…20mA, 4…20mA, 0…10Vdc
    • 6 module DIN rail mounting
    • Available with 230Vac, 115Vac and 20-30Vdc, 40-60Vdc, 90-140Vdc and 180-250Vdc auxiliary supply
    Call for Prices

  • IME TM1A - DC Current Isolated Transducer

    • Direct connected DC current transducers
    • Accuracy class 0.5 (class 0.2 frequency)
    • Input current 0…500µA up to 0…1.5Adc - bidirectional from ± 250µA to ± 750mA
    • Choice of output 0…20mA, 4…20mA, 0…10Vdc
    • 6 module DIN rail mounting
    • Available with 230Vac, 115Vac and 20-30Vdc, 40-60Vdc, 90-140Vdc and 180-250Vdc auxiliary supply
    Call for Prices

  • IME Tema FP - TM8P Programmable Isolated Transducer - True R.M.S. measurements

    • Fully programmable transducer
    • Single or 3-phase, balanced or unbalanced load or via voltage transformer
    • Current input via current transformer -/1A or -/5A
    • True R.M.S. measurements
    • 80…500Vac phase/phase
    • 50…300Vac single phase measured voltage
    • Programmable measured quantity - active power - reactive power - apparent power - power factor - phase angle - power demand – frequency
    • Analogue outputs 0…5mA, 0…10mA, 0…20mA, 4…20mA, 0…10V or 1…5Vdc
    • Accuracy class 0.5 (class 0.2 frequency)
    • LCD indicator for programming and display
    • All parameters programmable from front cover 3 keys
    • 8 module DIN rail mounting
    • Available with 230Vac, 115Vac and 20-150Vdc auxiliary supply
    Call for Prices

  • IME TM4U - AC Voltage Isolated Transducers - True RMS

    • Single phase AC
    • True R.M.S measurement
    • AC Voltage input
    • Accuracy 0.5 (20…120%.In)
    • Dip switch programmable current or voltage analogue output
    • Available with 230Vac, 115Vac and 20…150Vdc auxiliary supply
    Call for Prices

  • IME Tema U4 - TM3U - AC Alternating Voltage Isolated Transducer - RMS

    • Alternating voltage transducer
    • Single phase AC
    • AC Voltage input
    • Accuracy 0.5 (20…120%.In)
    • Dip switch programmable current or voltage analogue output
    • Available with 230Vac, 115Vac and 20…150Vdc auxiliary supply
    Call for Prices

Items 1 to 15 of 21 total

Page:
  1. 1
  2. 2

Grid  List