IME - Analogue and Digital Meters
IME Strategic UK Partner Products are available to our UK Customers.
-
IME RQ96SEL ANRB Sequencymeter for symmetric 3-phase network
- AC Voltage Supply :- 100..440V 50/60Hz
- Front Housing Protection :- IP52
- Terminal Protection :- IP20* with terminal covers
- Dimensions :- 96x96x69mm
-
IME AQ72E Single Phase Analogue Voltmeter for Alternating Voltage, 72x72mm, Scal...
- Direct indication of input voltage or primary voltage of external VT
- Moving iron equipment
- Direct connection 10...600V
- Input by external VT /100V - /110V
- Scale lenght 240°
- Accuracy class 1,5
-
IME AQ96M Single Phase Analogue Ammeter for Direct Current 96x96mm, Scale length...
- Direct indication of input current or primary current of external shunt
- Indication of any quantity, directly proportional to signals coming from transducers or sensors
- Moving coil equipment
- Direct connection 2...5A
- Connection by external shunt
-
IME AQ72M Single Phase Analogue Ammeter for Direct Current 72x72mm, Scale length...
- Direct indication of input current or primary current of external shunt
- Indication of any quantity, directly proportional to signals coming from transducers or sensors
- Moving coil equipment
- Direct connection 2...5A
- Connection by external shunt
-
IME AQ48M Single Phase Analogue Ammeter for Direct Current 48x48mm, Scale length...
- Direct indication of input current or primary current of external shunt
- Indication of any quantity, directly proportional to signals coming from transducers or sensors
- Moving coil equipment
- Direct connection 2...5A
- Connection by external shunt
-
IME AQ96E Single Phase Analogue Ammeter for Alternating Current, 96x96mm, Scale ...
- Direct indication of input current or primary current of external CT
- Moving iron equipment
- Direct connection 1...10A
- Input by external CT /5A or /1A
- Version for starting motor 2In or 5In
- Scale length 240°
-
IME AQ72E Single Phase Analogue Ammeter for Alternating Current, 72x72mm, Scale ...
- Direct indication of input current or primary current of external CT
- Moving iron equipment
- Direct connection 1...10A
- Input by external CT /5A or /1A
- Version for starting motor 2In or 5In
- Scale length 240°
-
IME ANT6 AL96DC Analogue Meters with Alarms for Direct Voltage 96x96mm
- Direct voltage measurement
- Display any proportional
- process variable
- Speed from tachometer dynamo measurement
- Direct input 1...200V
- Indication of primary current
- of external shunt
- 2 programmables alarms
- Alarms type: MIN+MAX or MIN1+MIN2 or MAX1+MAX2
-
IME ANT3 AL96DC Analogue Meters with Alarms for Direct Current 96x96mm
- Direct current measurement
- Display any proportional
- process variable
- Input for standard signal:1 – 5 - 10 - 20 – 4...20mA
- 2 programmables alarms
- Alarms type: MIN+MAX or MIN1+MIN2 or MAX1+MAX2
-
IME ANT4 AL96AC Analogue Meters with Alarms for Alternating Voltage 96x96mm
- Alternating voltage average value measurement with display related to rms value
- Direct input up to 500V or by VT/100V
- Indication of primary current of external VT
- 2 programmables alarms
- Alarms type: MIN+MAX or MIN1+MIN2 or MAX1+MAX2
-
IME ANT1 AL96AC Analog Meters With Alarms for Alternating Current 96x96mm
- Alternating current average value measurement with display related to rms value
- Input from CT/1A or /5A
- Indication of primary current of external CT
- 2 programmables alarms
- Alarms type: MIN+MAX or MIN1+MIN2 or MAX1+MAX2
-
IME Syncro 96L Synchronizing Meter with LED 96x96mm
- IP52 Rating
- Dimensions 96x96x105mm
- 16 red LED on 360°
- 15 round LED’s + 3 rectangular LED’s
-
IME RQ72SEL ANQB Sequencymeter for symmetric 3-phase network
- AC Voltage Supply :- 100..440V 50/60Hz
- Front Housing Protection :- IP52
- Terminal Protection :- IP20* with terminal covers
- Dimensions :- 72x72x69mm
-
IME RQ96M Single Phase Analogue Ammeter for Direct Current, 96x96mm, Scale lengt...
- Direct indication of input current or primary current of external shunt
- Indication of any quantity, directly proportional to signals coming from transducers or sensors
- Moving coil equipment
- Direct connection 50µA...60A (40A for RQ48M)
- Connection by external shunt
- 1A/60mV...6000A/60mV
- Connection by transducers or sensors
- 1...600mA – 0...5/10/20 – 4...20mA
- Lateral zero or central zero version
- Live zero or mechanically suppressed
- (4...20mA)
- Scale length 90°
- Accuracy cl.1,5
-
IME RQ72M Single Phase Analogue Ammeter for Direct Current, 72x72mm, Scale lengt...
- Direct indication of input current or primary current of external shunt
- Indication of any quantity, directly proportional to signals coming from transducers or sensors
- Moving coil equipment
- Direct connection 50µA...60A (40A for RQ48M)
- Connection by external shunt
- 1A/60mV...6000A/60mV
- Connection by transducers or sensors
- 1...600mA – 0...5/10/20 – 4...20mA
- Lateral zero or central zero version
- Live zero or mechanically suppressed
- (4...20mA)
- Scale length 90°
- Accuracy cl.1,5