IME - Current Transformers
IME Strategic UK Partner Products are available to our UK Customers.
-
IME TAIBB Solid Core Single Phase Measuring Current Transformer
- Ranges: 40 to 300A (5A Secondary), 40 to 200A (1A Secondary)
- Busbar window 16x12,5mm & ø 21mm Diameter able aperture
- Accuracy class :- cl.0,5 - 1 - 3
- Rated burden :- 1...7.5VA
-
IME TA221 Single Phase Current Transformer
- Measuring current transformer
- Ranges: 40 to 300A
- 5A or 1A Secondary output
- Busbar/Cable aperture : 20.5 x 10.5mm or Ø21mm
-
IME TA327 Solid Core Single Phase Measuring Current Transformer
- Passing cable/ bus bar primary
- Ranges: 50 to 600A
- 5A or 1A Secondary output
- Busbar/Cable aperture 32.5 x 10.5mm, 25.5 x 15.5mm or Ø27mm
- Accuracy: cl. 0.5 - 1 - 3
-
IME TA426 Single Phase Measuring Current Transformer
- Measuring current transformer
- Ranges: 150 to 800A
- 5A or 1A Secondary output
- Busbar/Cable aperture 40.5 x 12.5mm, 32.5 x 10.5mm or Ø26mm
-
IME TA432 Solid Core Single Phase Measuring Current Transformer
- Measuring current transformer
- Range 100 to 1000A
- Busbar window 40.5x10.5mm, 32.5x20.5mm & 25.5x25.5mm
- Cable aperture 32mm
-
IME TA540 Solid Core Single Phase Measuring Current Transformer
- Measuring current transformer
- Range 300 to 1200A (5A or 1A Secondary)
- Busbar window 50.5x12.5mm & 40.5x20.5mm
- Cable aperture 40mm
-
IME TASH TAS63 Single Phase Solid Core Measuring Current Transformer
- Measuring and protection current transformer (formerly TAS63)
- Ranges: 150 to 1600A (1A or 5A Secondary)
- Busbar window 64 x 19mm, 51 x 20mm, 41 x 21mm or 10 x 24mm
-
IME TASI TAS64 Single Core Single Phase Measuring Current Transformer
- Measuring current transformer (formerly TAS64)
- Ranges: 200 to 1600A (1A or 5A Secondary)
- Busbar window 64 x 11mm, 51 x 31mm
-
IME TASM (formerly TAS80) Single Phase Current Transformer
- Measuring and protection current transformer (formerly TAS80)
- Ranges: 300 to 2500A (1A or 5A Secondary)
- Busbar window 82 x 32mm
-
IME TASN (formerly TAS81) Single Phase Current Transformer
- Measuring current transformer
- Ranges: 400 to 2500A (1A or 5A Secondary)
- Busbar window 81 x 11mm, 64 x 31mm, 31 x 51mm
- Supplied with busbar mounting bracket
- Secondary terminals M4 screws and 6.3 x 0.8mm fast-on
-
IME TAQE TAQ1 Single Phase Winding Primary Current Transformer
- Measuring current transformer (formerly TAQ1)
- Ranges: 5 to 60A (1A or 5A Secondary)
- Wound primary
-
IME TAQA TAQ2 Single Phase Winding Primary Current Transformer
- Measuring current transformer
- Winding primary
- Primary current 5...80A
- Secondary current 1 - 5A
- Supplied with mounting feet
- Primary terminals M6 screw
- Secondary terminals M4 screws and 6.3 x 0.8mm fast-on
- Optional sealable terminal cover (ATACOP06)
- Optional DIN rail clip (ATADIN01)
- Weight 320g
-
IME TAQB TAQ6 Single Phase Winding Primary Current Transformer
- Measuring current transformer (formerly TAQ6)
- Ranges: 5 to 100A (1A or 5A Secondary)
- Wound primary
-
IME TAQC TAQ10 Wound Primary Single Phase Current Transformer
- Measuring current transformer (formerly TAQ10)
- Ranges: 5 to 300A (1A or 5A Secondary)
- Bar primary
-
IME TAQD (formerly TAQ20) Single Phase Current Transformer
- Measuring current transformer (formerly TAQ20)
- Ranges: 5 to 600A (1A or 5A Secondary)