IME - Current Transformers
IME Strategic UK Partner Products are available to our UK Customers.
-
IME TAQC...S (formerly TAQ10...S) High Accuracy Single Phase Current Transforme...
- High accuracy current transformer (formerly TAQ10...S)
- Ranges: 5 to 1500A (1A or 5A Secondary)
- Wound primary
-
IME TA327...S High Accuracy Single Phase Current Transformer
- High accuracy CT
- Ranges: 50 to 600A
- 5A or 1A Secondary output
- Busbar/Cable aperture 32.5 x 10.5mm, 25.5 x 15.5mm or Ø27mm
- Accuracy: cl. 0.2s - 0.2 - 0.5s
-
IME TA432...S High Accuracy Single Phase Current Transformer
- High accuracy current transformer
- Range 100 to 1000A
- Busbar window 40.5x10.5mm, 32.5x20.5mm & 25.5x25.5mm
- Cable aperture 32mm
-
IME TAWA (formerly TAS63P) Single Phase Protection Current Transformer
- Protection current transformer (formerly TAS63P)
- Ranges: 150 to 1600A (1A or 5A Secondary)
- Busbar window 64 x 19mm, 51 x 20mm, 41 x 21mm or 10 x 24mm
-
IME TAWB TAS80P Single Phase Protection Class 5P5 5P10 5P15 5P20 Current Transfo...
- Protection current transformer (formerly TAS80P)
- Ranges: 300 to 2500A (1A or 5A Secondary)
- Busbar window 82 x 32mm
-
IME TAWC TAS125P Single Phase Protection Class 5P5 5P10 5P15 5P20 Current Trans...
- Protection current transformer (formerly TAS125P)
- Ranges: 400 to 4000A (1A or 5A Secondary)
- Busbar window 127 x 54mm
- Secondary terminals M4 screws and 6.3 x 0.8mm fast-on
- Supplied with fixing feet
- Optional sealable terminal cover (ATACOP03)
- Weight 3600g
-
IME TAVA (formerly TAQ20P) Single Phase Current Transformer
- Protection current transformer (formerly TAQ20P)
- Ranges: 5 to 600A (1A or 5A Secondary)
- Bar primary
-
IME TAVB (formerly TAQ10P) Single Phase Current Transformer
- Protection current transformer (formerly TAQ10P)
- Ranges: 5 to 300A (1A or 5A Secondary)
- Bar primary (25x4mm)
-
IME TAEA BSA02/BSA03 Primary Winding Summation Current Transformer With 2 or 3 ...
- Summation current transformer BSA02
- Summates up to 2 or 3 equal inputs (1A or 5A Secondary)
- Accuracy class:cl.0,5-1
- Unequal inputs on request
-
IME BTA2 TAEB Primary Winding Summation Current Transformer (From 2 to 6 Equal ...
- Summation current transformer (formerly BTA2)
- Summates from 2 to 6 equal inputs
- 5A or 1A Secondary output
- Accuracy class 0.5
- Unequal inputs on request
-
IME DEL..N - Core Balanced Transformers from 28 to 310mm
- For Delta & RD earth leakage relays
- Cable Apertures : 28, 35, 80, 110, 110, 140, 150, 210, 310mm
-
IME TAQ6M Single Phase Winding Primary Current Transformer
- Wound Primary
- Primary current 5...40A
- Accuracy class: cl.0,5 - 1
- New Compact Dimensions
-
IME HT1B (formerly HT35A) - DC Current Transformers / Transducers - Torroidal
- Measures DC current with proportional DC analogue output, Hall Effect
- Cable aperture Ø35mm
- CT with built in transducer
- Measured current up to 1000A dc
- AC or DC supply voltage
-
IME HT1Bm - DC Current Transformers / Transducers - Torroidal
- Measures DC current with proportional DC analogue output, Hall Effect
- Auxialry output to power up to 3 HT1Bs units
- Cable aperture Ø35mm
- CT with built in transducer
- Measured current up to 1000A dc
- AUX output 15Vdc
- AC or DC supply voltage
-
IME HT1Bs - DC Current Transformers / Transducers - Torroidal
- DC current transformer/transducer - to measure DC current and deliver a proportional DC analogue output
- DC Current measurement, Hall Effect
- 35mm (HT1Bs) internal aperture
- Current transformer with built in transducer
- Measured current up to 1000A dc
- AUX input 15Vdc