IME - Current Transformers
IME Strategic UK Partner Products are available to our UK Customers.
-
IME TAPQ Horizontal Mounting (formerly TAS102BPH) Single Phase Current Transform...
- Protection current transformer (formerly TAS102BPH)
- Ranges: 800 to 3000A (1A or 5A Secondary)
- Busbar window 54 x 102mm
-
IME TAPQ TAS102BP Single Phase Protection 5P5/5P10 Stadium Current Transformer
- Protection current transformer
- Primary current 800...3000A
- Secondary current 1 - 5A
- Busbar window 102 x 54mm
- Accuracy: cl.5P5 - 5P10
- Rated burden:
- 10...20VA (5P5)
- 4...6VA (5P10)
- Supplied with busbar mounting clamps
- Secondary pillar screw terminals
- Optional sealable terminal cover (ATACOP04)
- Weight 1,000g
-
IME TAWC TAS125P Single Phase Protection Class 5P5 5P10 5P15 5P20 Current Trans...
- Protection current transformer (formerly TAS125P)
- Ranges: 400 to 4000A (1A or 5A Secondary)
- Busbar window 127 x 54mm
- Secondary terminals M4 screws and 6.3 x 0.8mm fast-on
- Supplied with fixing feet
- Optional sealable terminal cover (ATACOP03)
- Weight 3600g
-
IME TAWB TAS80P Single Phase Protection Class 5P5 5P10 5P15 5P20 Current Transfo...
- Protection current transformer (formerly TAS80P)
- Ranges: 300 to 2500A (1A or 5A Secondary)
- Busbar window 82 x 32mm
-
IME TAWA (formerly TAS63P) Single Phase Protection Current Transformer
- Protection current transformer (formerly TAS63P)
- Ranges: 150 to 1600A (1A or 5A Secondary)
- Busbar window 64 x 19mm, 51 x 20mm, 41 x 21mm or 10 x 24mm
-
IME TASS...3S Horizontal Mounting(formerly TAS127BHS) High Accuracy Single Phase...
- Measuring current transformer (formerly TAS127BHS)
- Ranges: 400 to 4000A (1A or 5A Secondary)
- Busbar window 127 x 54mm
-
IME TASS...S (formerly TAS127BS) High Accuracy Single Phase Current Transformer
- Measuring current transformer (formerly TAS127BS)
- Ranges: 400 to 4000A (1A or 5A Secondary)
- Busbar window 127 x 54mm
-
IME TASR...3S Horizontal Mounting (formerly TAS127HS) High Accuracy Single Phase...
- Measuring current transformer (formerly TAS127HS)
- Ranges: 400 to 4000A (1A or 5A Secondary)
- Busbar window 127 x 38mm
-
IME TASR...S (formerly TAS127S) High Accuracy Single Phase Current Transformer
- Measuring current transformer (formerly TAS127S)
- Ranges: 400 to 4000A (1A or 5A Secondary)
- Busbar window 127 x 38mm
-
IME TAMP...3S Horizontal Mounting (formerly TAS102HS) High Accuracy Single Phas...
- Measuring current transformer (formerly TAS102HS)
- Ranges: 800 to 3000A (1A or 5A Secondary)
- Busbar window 102 x 38mm
-
IME TAMP...S (formerly TAS102S) High Accuracy Single Phase Current Transformer
- Measuring current transformer (formerly TAS102S)
- Ranges: 800 to 3000A (1A or 5A Secondary)
- Busbar window 102 x 38mm
-
IME TASO...3S Horizontal Mounting (formerly TAS84HS) High Accuracy Single Phase ...
- Measuring current transformer (formerly TAS84HS)
- Ranges: 150 to 2500A (1A or 5A Secondary)
- Busbar window 84 x 34mm
-
IME TASO...S (formerly TAS84S) High Accuracy Single Phase Current Transformer
- Measuring current transformer (formerly TAS84S)
- Ranges: 150 to 2500A (1A or 5A Secondary)
- Busbar window 84 x 34mm
-
IME TASL...3S Horizontal Mounting (formerly TAS65HS) High Accuracy Single Phase ...
- Measuring and protection current transformer (formerly TAS65HS)
- Ranges: 200 to 2000A (1A or 5A Secondary)
- Busbar window 65 x 32mm
-
IME TASL...S (formerly TAS65S) High Accuracy Single Phase Current Transformer
- Measuring and protection current transformer (formerly TAS65S)
- Ranges: 200 to 2000A (1A or 5A Secondary)
- Busbar window 65 x 32mm