IME - kWh Energy Meters
As the UK partner for IME Italy we have access to their extensive range of energy meters including MID Certified kWh meters for billing applications.
IME Strategic UK Partner Products are available to our UK Customers.
-
IME Conto D2 Class 1 Single Phase Network kWh Energy Meter (Not MID Certificated...
- Kilowatt hour / active energy meter
- 2 module wide
- DIN rail mounted
- Single phase network
- Input current 10(63)A
- Input voltage 230V
- Active energy class B (EN50470)
- Reactive energy class 2 (EN60253-23)
- Total active energy, Partial active energy (resettable), Current, Voltage, Active power (kW), Frequency, Power factor, Hours run meter (resettable)
- LCD Display 5+1= 999999.9
- Self supplied auxiliary
- Pulse or RS485 Modbus RTU (depending on model)
-
IME Conto 72-Sh Single and Three Phase Network Panel Mounted kWh Network Meter -...
- Kilowatt hour meter / active energy meter
- 72 x 72mm flush panel mounting
- Single phase & 3 phase (3 or 4 wire) network unbalanced load
- Active energy class 1 (EN62053-21)
- Reactive energy class 2 (EN62053-23)
- Power demand
- Power max demand (resettable)
- Partial active and reactive energy (resettable)
- Phase Current
- Phase to phase and phase to neutral voltage
- Frequency
- Phase active power
- Phase reactive power
- 3 phase active/reactive and apparent power
- Power factor
- –/1A or –/5A current transformer operated
- 190…440V 50/60Hz measured voltage
- 8 digit LCD display
- Self supplied auxiliary
- Pulsed output
- Programmable CT ratios
-
IME Conto D4-Pd Class 1 Three Phase Network 63 Direct Connected kWh Energy Meter...
- Kilowatt hour / active energy meter
- 4 module DIN rail mounting
- Direct connection up to 63A
- 3 phase 3 or 4 wire network unbalanced load
- Active energy class 1
- Reactive energy class 2
- Total active energy
- Total reactive energy
- Partial active energy (resettable)
- Partial reactive energy (resettable)
- Phase current
- Phase – neutral voltage
- Phase – phase voltage
- Active power (KW)
- Reactive power (KVar)
- Apparent power (KVA)
- Phase active power (KW)
- Phase reactive power (KVar)
- Active power demand
- Active power max demand
- Frequency
- Power factor
- Hours run meter (resettable)
- 230V/400V 50Hz measured voltage
- 8 digit LCD display
- Self supplied auxiliary
- Pulse or RS485 output
-
IME Conto D4-Pt Single-Phase & Three-Phase 3-4 Network kWh Meter - Connecti...
- Kilowatt hour / active energy meter
- 4 module DIN rail mounting
- -/5A current transformer operated
- 3 phase 4 wire network unbalanced load
- Active energy class 1
- Reactive energy class 2
- Total active energy
- Total reactive energy
- 230V/400V 50Hz measured voltage
- 8 digit LCD display
- Programmable CT ratio
- Auxiliary supply 230V 50/60Hz
- Pulse and RS485 output
-
Conto D4-Pt M-Bus
- Kilowatt hour / active energy meter
- 4 module DIN rail mounting
- -/5A current transformer operated
- 3 phase 4 wire network unbalanced load
- Active energy class 1
- Reactive energy class 2
- Total active energy
- Total reactive energy
- 230V/400V 50Hz measured voltage
- 8 digit LCD display
- Programmable CT ratio
- Auxiliary supply 230V 50/60Hz
- Mbus output
-
IME IF4C001 Conto Imp Pulse Acquisition 4 Module To RS485 communication
- Pulse imput coming from energy, gas, water, heat meters, etc
- 12 pulse inputs SPST - NO contacts (energy, gas, water and heat meters)
- 12 non resettable independent counting registers (max 9 digits each)
- 3 different configuration
- RS485 communication MODBUS/JBUS
- Up to 255 units may be connected to a bus system
- Data held in memory in event of power failure
-
IME Conto D4-Sh Class 1 Single Phase & Three Phase Network kWh Meter - CT Co...
- Kilowatt hour / active energy meter
- 4 module DIN rail mounting
- Single phase & 3 phase (3 or 4 wire) network unbalanced load
- –/1A ,-/5A or 0.333V current transformer operated
- 190…440V 50/60Hz measured voltage
- 8 digit LCD display
- Self supplied auxiliary
- Programmable CT ratios
- Pulsed or RS485 output
-
IME Conto D6 Three Phase Kilowatt Hour Energy Meter
- DIN Rail Mounting - 6 Module
- Three Phase network, 4wire
- Direct connected : 230(400)V…240(415)V 125A
- Programmable pulse output
- RS485 communication
- Sealable terminal blocks