NEED HELP ? - Call : +44 (0)1245 428500 or email : sales@rayleigh.com
OFFICE HOURS : 9:00am - 5:30pm GMT/BST Monday to Friday

Rayleigh Instruments - Multifunction Meters

Multifunction Energy Meters for single-phase and three-phase MID and non-MID energy monitoring applications - direct connection or current transformer operated with a range of communication protocols including pulse, Modbus and Mbus. DIN rail mounting, panel mounting models available.

Click Here to Download our Energy Meters and Current Transformers Brochure

15 Item(s)

Grid  List 

  • IME Conto D4-Sh Class 1 Single Phase & Three Phase Network kWh Meter - CT Co...

    • Kilowatt hour / active energy meter
    • 4 module DIN rail mounting
    • Single phase & 3 phase (3 or 4 wire) network unbalanced load
    • –/1A ,-/5A or 0.333V current transformer operated
    • 190…440V 50/60Hz measured voltage
    • 8 digit LCD display
    • Self supplied auxiliary
    • Programmable CT ratios
    • Pulsed or RS485 output
    Call for Prices

  • IME Conto 72-Sh Single and Three Phase Network Panel Mounted kWh Network Meter -...

    • Kilowatt hour meter / active energy meter
    • 72 x 72mm flush panel mounting
    • Single phase & 3 phase (3 or 4 wire) network unbalanced load
    • Active energy class 1 (EN62053-21)
    • Reactive energy class 2 (EN62053-23)
    • Power demand
    • Power max demand (resettable)
    • Partial active and reactive energy (resettable)
    • Phase Current
    • Phase to phase and phase to neutral voltage
    • Frequency
    • Phase active power
    • Phase reactive power
    • 3 phase active/reactive and apparent power
    • Power factor
    • –/1A or –/5A current transformer operated
    • 190…440V 50/60Hz measured voltage
    • 8 digit LCD display
    • Self supplied auxiliary
    • Pulsed output
    • Programmable CT ratios
    Call for Prices

  • IME Conto D4-Pt Single-Phase & Three-Phase 3-4 Network kWh Meter - Connecti...

    • Kilowatt hour / active energy meter
    • 4 module DIN rail mounting
    • -/5A current transformer operated
    • 3 phase 4 wire network unbalanced load
    • Active energy class 1
    • Reactive energy class 2
    • Total active energy
    • Total reactive energy
    • 230V/400V 50Hz measured voltage
    • 8 digit LCD display
    • Programmable CT ratio
    • Auxiliary supply 230V 50/60Hz
    • Pulse and RS485 output
    Call for Prices

15 Item(s)

Grid  List