Rayleigh Instruments - Multifunction Meters
Multifunction Energy Meters for single-phase and three-phase MID and non-MID energy monitoring applications - direct connection or current transformer operated with a range of communication protocols including pulse, Modbus and Mbus. DIN rail mounting, panel mounting models available.
-
IME Nemo 96HD+ Panel Mounted Single & Three Phase Network Multifunction Ener...
- DIN 96 panel mounted
- High-definition backlit LCD display
- Single phase or 3-phase, 3 or 4-wire unbalanced load operation
- Measured Voltage 80-690V 50/60 Hz (phase to phase)
- -/1A or -/5A CT Input selectable
-
IME Nemo D4-Le Single & Three Phase Network Din Rail Multifunction Energy Me...
- 4 module wide DIN rail mounting
- Single & 3 phase (3 or 4 wire) network unbalanced load
- 3-phase line 80...500V (phase-phase)
- Connection on dedicated CT
- –/1A or –/5A (selectable) CT operated
- Programmable external CT and VT ratio
- Active energy class 0.5
- Pulse output/alarm/state switching
- RS485 communication
-
Inepro PRO1-Standard 45A MID Certified Single Tariffs Single Phase Network Mult...
- Single phase network active energy meter
- MID Certified (B and D)
- 45A Direct connected
- Single Tariff
- 17.5mm wide/1 Module
- Din Rail Mounted
- LCD Display 5+2= 99999.99
- Measured voltage 230V 50 Hz
- Calculation of total energy : Forward, Forward+Reverse, Forward-Reverse, Reverse-Forward, Reverse
- Pulse output (settable S0)
-
IME Nemo 96HDe Panel Mounted Single & Three Phase Network Multifunction Mete...
- DIN 96 panel mounted
- Backlit LCD display
- Three-phase line 50...460V
- Connection on dedicated CT
- Programmable external CT ratio
- Active energy cl.1
- Pulse + RS485 ModBus output
-
IME Nemo 96 EA Network and Power Quality Analyser - Single & Three Phase
- DIN 96 panel mounted
- High-definition LCD display
- Single phase or Three phase
- 3 or 4-wire unbalanced load operation
- RS485 Modbus RTU/TCP
- 4 x Plug-in Modules optional
- 80…690V 50/60 Hz (phase to phase)
- -/1A or -/5A CT Input
-
IME Nemo 96HDLe Single & Three Phase Network Multifunction Energy Meter
- High-definition LCD display
- Three-phase line 80...500V
- Programmable CT & VT ratio
- Active energy cl.0.5
- Pulse output
- RS485 ModBus RTU/TCP
- Single Port for Extension Modules
-
IME - Nemo 72-b Single or Three-Phase 4-Wire Unbalanced Multifunction Network Mo...
- DIN 72 panel mounted
- High-definition display
- Single phase or Three-phase
- Programmable primary CT
- True RMS value measurement
- 2 Programmable alarms
- Reverse power alarm
-
IME Nemo 72-Le Multifunction Energy Meter with Active Energy Count cl.0.5 / Reac...
- High-definition backlit display
- Single phase or 3-phase operation
- 3-phase line 80…500V
- Connection on dedicated CT
- Active energy class 0.5
- ModBus RTU/TCP or BACNET
-
IME Nemo D4-e Single Phase & Three Phase Multifunction Network Monitor
- High-definition backlit display
- Three-phase line 50...460V (phase-phase)
- Dedicated CT connection
- Programmable CT ratio
- Active energy cl.1
- Phase sequence correction, diagnostic
-
IME Nemo 96HD Panel Mounted Single & Three Phase Network 0.5 Accuracy Class ...
- DIN 96 panel mounted
- High-definition backlit LCD display
- Single phase or 3-phase, 3 or 4-wire unbalanced load operation
- Measured Voltage 80-500V 50/60 Hz (phase to phase)
- -/1A or -/5A CT Input selectable
-
IME Conto D4-Pt Single-Phase & Three-Phase 3-4 Network kWh Meter - Connecti...
- Kilowatt hour / active energy meter
- 4 module DIN rail mounting
- -/5A current transformer operated
- 3 phase 4 wire network unbalanced load
- Active energy class 1
- Reactive energy class 2
- Total active energy
- Total reactive energy
- 230V/400V 50Hz measured voltage
- 8 digit LCD display
- Programmable CT ratio
- Auxiliary supply 230V 50/60Hz
- Pulse and RS485 output
-
IME Conto 72-Sh Single and Three Phase Network Panel Mounted kWh Network Meter -...
- Kilowatt hour meter / active energy meter
- 72 x 72mm flush panel mounting
- Single phase & 3 phase (3 or 4 wire) network unbalanced load
- Active energy class 1 (EN62053-21)
- Reactive energy class 2 (EN62053-23)
- Power demand
- Power max demand (resettable)
- Partial active and reactive energy (resettable)
- Phase Current
- Phase to phase and phase to neutral voltage
- Frequency
- Phase active power
- Phase reactive power
- 3 phase active/reactive and apparent power
- Power factor
- –/1A or –/5A current transformer operated
- 190…440V 50/60Hz measured voltage
- 8 digit LCD display
- Self supplied auxiliary
- Pulsed output
- Programmable CT ratios
-
IME Conto D2 Class 1 Single Phase Network kWh Energy Meter (Not MID Certificated...
- Kilowatt hour / active energy meter
- 2 module wide
- DIN rail mounted
- Single phase network
- Input current 10(63)A
- Input voltage 230V
- Active energy class B (EN50470)
- Reactive energy class 2 (EN60253-23)
- Total active energy, Partial active energy (resettable), Current, Voltage, Active power (kW), Frequency, Power factor, Hours run meter (resettable)
- LCD Display 5+1= 999999.9
- Self supplied auxiliary
- Pulse or RS485 Modbus RTU (depending on model)
-
IME Conto D4-Sh Class 1 Single Phase & Three Phase Network kWh Meter - CT Co...
- Kilowatt hour / active energy meter
- 4 module DIN rail mounting
- Single phase & 3 phase (3 or 4 wire) network unbalanced load
- –/1A ,-/5A or 0.333V current transformer operated
- 190…440V 50/60Hz measured voltage
- 8 digit LCD display
- Self supplied auxiliary
- Programmable CT ratios
- Pulsed or RS485 output
-
Rayleigh Instruments RI-D18-100-C 100A Direct Connect Single Phase kWh Meter wit...
- 100A direct connected single phase
- High definition LCD display
- 18mm wide DIN rail mounting
- Import active energy measurement
- RS485 Modbus communication
- Single module width DIN rail mounted